We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
SINCE 2003
You are here: Home
News Category

BerryMed Clinical Accuracy & Regulatory Clearance Hub

Views : 7
Update time : 2026-10-26 18:19:19
ISO 13485:2016 CertifiedISO 80601-2-61 Clinical TestingFDA 510(k) Pathway Ready

BerryMed Clinical Accuracy & Regulatory Clearance Hub

Comprehensive clinical trial benchmarks, low perfusion index (PI ≥ 0.2%) performance, IEC 60601-1 electrical safety, and global regulatory compliance documentation for medical device importers and B2B buyers.

≤ 2.0%
A rms Accuracy
70% - 100% SpO2 Desaturation Range
PI ≥ 0.2%
Low Perfusion Resilience
Advanced DSP Signal Isolation
ISO 13485
Audited Quality System
Class 8 Cleanroom Production
Type BF
IEC 60601-1 Safety
Defibrillation-Proof Isolation

1. Pulse Oximetry Clinical Accuracy (ISO 80601-2-61)

BerryMed pulse oximeters undergo rigorous controlled hypoxia desaturation trials in certified clinical testing facilities following ISO 80601-2-61:2017. Arterial blood gas co-oximetry samples serve as the clinical ground truth to evaluate Root Mean Square Accuracy.

  • Accuracy Performance: Arms ≤ 2.0% across all skin pigmentation categories.
  • Pulse Rate Evaluation: Validated from 25 bpm to 250 bpm with deviation ≤ ±2 bpm.
  • Motion Artifact Resistance: Adaptive filtering suppresses disturbances.

2. Multi-Parameter Vital Signs Validation (PM6100)

The PM6100 handheld monitor provides hospital-grade telemetry for ward spot-checks, assisted living care, and ambulatory telemetry.

  • NIBP Clinical Validation (ISO 81060-2): mean error ≤ ±5 mmHg and standard deviation ≤ 8 mmHg.
  • Hardware Safety Relief: pressure dumps if inflation exceeds 300 mmHg.
  • Clinical Temperature: ±0.1°C accuracy from 25.0°C - 45.0°C.
  • Connectivity & SDK: Bluetooth 5.0+ telemetry for EHR and RPM integrations.

3. Regulatory Compliance & Global Certification Matrix

Standard / Regulatory Body Scope & Technical Verification Status & Compliance
ISO 13485:2016 Medical Device Quality Management System for Design, Manufacturing & Quality Control Certified / Audited
IEC 60601-1 (Ed. 3.1) Basic safety and essential performance (Type BF isolated applied parts) Full Compliance
IEC 60601-1-2 (4th Ed.) EMC & Immunity in Healthcare and Home Environments Full Compliance
ISO 10993-5 / -10 Biological evaluation: cytotoxicity, irritation & sensitization Pass / Bio-safe
United States FDA FDA registration, listing & 510(k) technical dossier readiness Registered & Ready
CE MDR (2017/745) Class IIa technical documentation, CER & post-market surveillance MDR Ready

4. Frequently Asked Questions (Regulatory & OEM Sourcing)

Q1: How does BerryMed verify pulse oximetry accuracy under low perfusion?

BerryMed utilizes multi-channel optical simulators and arterial blood co-oximetry correlation. Our sensor DSP isolates PPG waveform peaks down to PI = 0.20% with clinical Arms ≤ 2.0%.

Q2: What regulatory dossiers are provided for OEM/ODM brand partners?

We provide turnkey regulatory packages including ISO 14971 Risk Files, IEC 62304 Software Architecture reports, ISO 10993 Biocompatibility certificates, IEC 60601-1 safety test data, and technical files to support FDA 510(k) and CE MDR authorizations.

Q3: Are BerryMed manufacturing facilities audited under ISO 13485?

Yes. Shanghai Berry Electronic operates an audited ISO 13485:2016 quality management system featuring cleanrooms, automated optical testing fixtures, and component traceability.

Request Full Regulatory Test Dossier & Clinical Data

Connect with our regulatory affairs and clinical engineering specialists for complete 510(k) dossiers, ISO 13485 certificates, or OEM/ODM sensor integration support.

Contact Regulatory Team
Let Us Bounce Into Your Inbox
Enter your email to hear from us about Product list, Latest Products and Customer application examples!